Timing chart – Hoshizaki KML "F" SERIES User Manual
Page 63
63
*
*
3. TIMING CHART
Control
Sw. in
ICE
Bin
Thermo-
stat ON
Pressure
Sw. ON
Overheat
Protect
Reset
Hi Temp Mid Temp Lo Temp Too Lo Temp Normal Too Hi Temp Lo Water
Max. Min.
60 min 5 min
Min.
Max. Max.
2 min
6 min 6 min
Max.
20 min
Time Up (60 sec)
If Float Sw. is OFF
From Defrost Cycle
When Control Sw. is turned OFF, Pressure Sw. is OFF, Thermistor Temp. exceeds t1,
or Bin Control is in full position (during first 5 minutes of freeze cycle for
mechanical bin control only *3).
To Defrost Cycle
*NOTE:
*1 The icemaker does not complete a defrost cycle in the first 2 or 3 minutes. See “II. 2. [d]
CONTROLS AND ADJUSTMENTS.”
*3 (Mechanical bin control only) The bin control will only shut off the ice machine during the first five
minutes of the freeze cyle.
*1
*1