beautypg.com

Hoshizaki KML "F" SERIES User Manual

Page 102

background image

102

13. REMOVAL AND REPLACEMENT OF WATER VALVE

1) Turn off the power supply.

2) Close the Water Supply Line Shut-off Valve.

3) Remove the Front Panel.

4) Remove the Valve Outlet Tubing by releasing the Clamp.

5) Remove the Bracket from the unit.

6) Remove the Fitting Nut and Water Valve.

7) Disconnect the Terminals from the Water Valve.

8) Install the new Water Valve, and replace the removed parts in the reverse order of
which they were removed.

9) Open the Water Supply Line Shut-off Valve.

10) Turn on the power supply.

11) Check for leaks.

12) Replace the Front Panel in its correct position.