2nd Cycle and after with pump drain
IMPORTANT
Freeze cycle time is limited to 60 minutes even
if Float Switch does not open.
1. Float Switch opens and signals to complete
 freeze cycle.
 Drain timer starts counting.
2. Drain timer stops counting.
 Pump drain is completed
3. Thermistor reads 48° F.
 Defrost Timer starts
 counting.
IMPORTANT
Water Valve
opening is limited to 6
minutes.
5. After the first 5 minutes in freeze cycle.
 Ready to complete freeze cycle when Float
 Switch circuit opens.
4. Defrost Timer stops counting.
 Defrost cycle is completed and freeze cycle
 starts.
IMPORTANT
Board never accepts freeze completion signal
within the first 5 minutes in freeze cycle.
IMPORTANT
1. Board never accepts defrost completion
 signal within the first 2 minutes in defrost
 cycle.
2. Defrost cycle time is limited to 20 minutes
 even if Defrost Timer does not stop counting.