7-2. ERROR CODES
“E-20-A”
• Pressure Switch
• If fan is not running, have pressure switch checked; should be
“FAN SENSOR
failure
open circuit if no air pressure
STUCK
• wiring problem
• If fan is running, wiring error, or relay on I/O board closed
CLOSED”
• I/O board failure
“E-20-B”
• Pressure Switch
• Press power button to vat off and back on again, if E-20-B
“NO DRAFT”
failure/hose loose
persists, have pressure switch checked; should be open circuit
“CHECK
• Draft Fan failure/
if no air pressure; make sure hose is connected to fan and
FAN”
low voltage
pressure switch
• Flue or hood
• Have draft fan checked; low voltage going to fan
obstructions
• check the fryer flue and hood system for obstructions
“E-20-D”
• Failure to ignite/
• Press power button to vat off and back on again, if E-20-D
“IGNITION”
no flame sense
persists, check gas line connections; check gas shut-off valve;
“FAILURE”
have ignition module checked; gas valve checked; flame sensor
gap checked; gas valve and ignition module wiring checked
“E-21”
• Slow heat recovery
• Have a certified service technician check the fryer for correct
voltage to the unit; have heat circuit checked; have unit
checked for loose or burnt wire
“E-22”‘NO
• Burner not igniting
• Have gas valve and heat circuit checked
HEAT” “CHECK
GAS VALVE”
“E-41”, “E-46”
• Programming
• Press power button to vat off and back on again, if any
failure
of the error codes, have the controls re-initialized; if error code
persists, have the control board replaced
“E-47”
• Analog converter
• Press power button to vat off and back on again, if “E-47”
chip or 12 volt
persists, have the I/O board, or the PC board replaced; if
supply failure
speaker tones are quiet, probably I/O board failure; have the
I/O board replaced
“E-48”
• Input system error
• Have PC board replaced
“E-54C”
• Temperature input
• Turn switch to OFF, then back to ON; have control PC board
error
replaced if “E-54C” persists
“E-60”
• AIF PC board not
• Press power button to vat off and back on again if “E-60”
communicating with
persists, have the connector between the PC boards checked;
control PC board
replace AIF PC board or control PC board if necessary
DISPLAY
CAUSE
CORRECTION
7-4
809