7-2. ERROR CODES
In the event of a control system failure, the digital display shows an
error message. The message codes are shown in the DISPLAY
column below. A constant tone is heard when an error code is
displayed, and to silence this tone, press any button.
DISPLAY
CAUSE
CORRECTION
“E-4”
• Control board
• Turn switch to OFF position, then turn switch back to ON;
overheating
if display shows “E-4”, the control board is getting too hot;
check the louvers on each side of the unit for obstructions
“E-5”
• Oil overheating
• Turn switch to OFF position, then turn switch back to ON;
if display shows “E-5”, the heating circuits and temperature
probe should be checked
“E-6A”
• Temperature
• Turn switch to OFF position, then turn switch back to ON;
probe open
if display shows “E-6A”, the temperature probe should be
checked
“E-6B”
• Temperature
• Turn switch to OFF position, then turn switch back to ON;
probe shorted
if display shows “E-6B”, the temperature probe should be
checked
“E-10”
• High limit
• Press the red reset button under the right side of the controls;
if high limit does not reset, high limit must be replaced
“E-15”
Drain switch
Make sure drain knob is completely pushed-in; if E-15 persists,
have drain switch checked
“E-18-A”
• Left level sensor open • Turn switch to OFF position, then turn switch back to ON; if
“E-18-B”
• Right level sensor open display still indicates a failed sensor, have the connectors
“E-18-C”
• Both level sensors open checked at the control board; have sensor checked & replace if
necessory