1-3. INTRODUCTION
Installation of the KFC Computerized Control Panel on existing
Henny Penny gas pressure fryers.
Disconnect the fryer from the electrical supply source
before beginning panel conversion.
Failure to disconnect the fryer from the supply source
could result in electrical shock.
The fryer internal wiring is numbered to correspond to the
numbers on the wiring diagram, Figure 1.
1-4. CONTROL PANEL WIRE
REMOVAL
A. Remove the four screws holding the existing control panel in
place.
B. Position the control panel for servicing by placing the lower
edge of the control panel on top of fryer frame and door.
C. Identify the locations of the following wires. Reference wire
diagram Figure 1.
Wire
Wire Number
Pin Number
Location
9 Pin Conenctor
Neutral
2
1
Main Power Switch
Motor
34
9
Main Power Switch
Motor
33
7
Main Power Switch
L 1
1
3
Main Power Switch
Fan
10
4
Main Power Switch
Solenoid
31
6
Main Timer
Solenoid
32
8
Soft/Crisp Switch
Hi Limit & Fan
8
2
Wiring Harness
Gas Valve
12
5
Gas Valve
1-2
304