beautypg.com

B. facing material – Heat & Glo Fireplace SL-550TV-IPI-E User Manual

Page 32

background image

Heat & Glo • SL-550 / 750 / 950TV-IPI-E • 2119-900 Rev. J • 12/09

32

B. Facing Material

• Metal front faces may be covered with non-combustible

materials only.

• Facing and/or fi nishing materials must not interfere with

air fl ow through louvers, operation of louvers or doors,
or access for service.

• Facing and/or fi nishing materials must never overhang

into the glass opening.

• Observe all clearances when applying combustible

materials.

• Seal joints between the fi nished wall and appliance top

and sides using a 300 °F minimum sealant. Refer to
Figure 13.5 and 13.6.

WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specifi ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.

0 in.

0 in.

0 in.

Finish wall material may be

combustible - Top and Sides

High Temperature Sealant (300° F/149° C min.)

Top and Side Seal Joint

1 in.

NON-COMBUSTIBLE STRIP SHIPPED WITH UNIT

Figure 13.5 Noncombustible Facing Diagram

Figure 13.6 Noncombustible Facing Diagram

0 INCH
(0 mm)

1 INCH

(25 mm)

FINISH WALL MATERIAL

MAY BE COMBUSTIBLE

TOP AND SIDES

TOP SEAL

JOINT

SIDE SEAL

JOINT

NON-COMBUSTIBLE STRIP
SHIPPED WITH UNIT

This manual is related to the following products: