Heat & Glo • SL-550 / 750 / 950TV-IPI-E • 2119-900 Rev. J • 12/09

21

D. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-
ances as specifi ed. Framing or fi nishing material closer than
the minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc).

Combustible Mantels

5

6

7

8

9

10

3

4

5

12

11

10

9

8

7

6

TOP OF HOOD OR FIREPLACE OPENING

4

12

13

11

32

CEILING

2-7/8 IN.
MINIMUM

1/2 IN.
MINIMUM

TOP VIEW

3 FT.
MAXIMUM

Note: Clearance from
opening Alcove/Mantel leg.

5-3/8 IN.

MINIMUM

3 IN.
MINIMUM

TOP VIEW

UNLIMITED

Note: Clearance from
opening Alcove/Mantel leg.

Figure 5.6 Clearance to Wall Projection

(Acceptable on one side of opening.)

1/2 in.
SHEETROCK

3-1/2 in.

1/2 in.

NON-COMBUSTIBLE ZONE

NON-COMBUSTIBLE
BOARD SHIPPED
WITH APPLIANCE

Figure 5.4 Non-Combustible Zone

Note: All measurements are in inches.

Figure 5.3 Minimum Vertical and Maximum Horizontal

Dimensions of Combustibles

Figure 5.5 Combustible Mantel Leg or Wall Projections

(Acceptable on both sides of opening)