beautypg.com

Technical specifications, Quickspecs – HP ProLiant DL785 User Manual

Page 37

background image

System Unit

System Unit

System Unit

System Unit

Dimensions

Dimensions

Dimensions

Dimensions (H x W x D)
(with bezel)

12.04 x 17.32 x 27.4 in (30.58 x 44 x 69.6cm)

Weight

Weight

Weight

Weight
(approximate)

Maximum
(all hard drives, power
supplies, and processors
installed)

160lb (72 kg)

Minimum
(one hard drive, 2 power
supply, and 4 processor
modules installed)

147 lb (67 kg)

Input Requirements

Input Requirements

Input Requirements

Input Requirements
(per 3 power supplies non
redundant)

Rated Line Voltage

90 - 132 VAC
180 - 264 VAC

Rated Input Current

24A @ 100 VAC
14A @ 200 VAC

Rated Input Frequency

47 to 63 Hz

Rated Input Power

2400W @ 100-120 VAC
2800W @ 200-240 VAC

BTU Rating

BTU Rating

BTU Rating

BTU Rating

Maximum

8189 BTU/hr @ 100-120 VAC
9554 BTU/hr @ 200-240 VAC

Power Specifications

Power Specifications

Power Specifications

Power Specifications

To review typical system power ratings use the Power Calculator which is
available via the online tool located at URL:

http://h30099.www3.hp.com/configurator/calc/Power%
20Calculator%20Catalog.xls

Click on the system of interest. Example: DL785 G5
Follow the instructions of the next screens

Power Supply Output

Power Supply Output

Power Supply Output

Power Supply Output (per
power supply)

Rated Steady-State Power

800 W (at 100 VAC),
1200 W (at 200 VAC)

Maximum Peak Power

800 W (at 100 VAC),
1200 W (at 200 VAC)

System Inlet Temperature

System Inlet Temperature

System Inlet Temperature

System Inlet Temperature Operating

10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed. System performance may be reduced if
operating with a fan fault or above 30°C (86°F).

Non-operating

-30° to 60° (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).

Relative Humidity

Relative Humidity

Relative Humidity

Relative Humidity
(non-condensing)

Operating

10% to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bult temperature, non-
condensing.

Non-operating

5% to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non
condensing.

QuickSpecs

HP ProLiant DL785 Generation 5 (G5)

HP ProLiant DL785 Generation 5 (G5)

HP ProLiant DL785 Generation 5 (G5)

HP ProLiant DL785 Generation 5 (G5)

Technical Specifications

DA - 13046 Worldwide — Version 4 — May 21, 2008

Page 37