Technical specifications, Quickspecs, Hp storageworks 1500 cs modular smart array – HP 1500 cs User Manual
Page 24

1500 cs Modular Smart
1500 cs Modular Smart
1500 cs Modular Smart
1500 cs Modular Smart
Array
Array
Array
Array
LED Indicators on Front
LED Indicators on Front
LED Indicators on Front
LED Indicators on Front
(4)
System heartbeat
System UID
Power On/Standby
Fault detected in enclosure
LED Indicators on Rear
LED Indicators on Rear
LED Indicators on Rear
LED Indicators on Rear
Panel
Panel
Panel
Panel (7)
System UID
SCSI Module Power indicator (1 per SCSI I/O module)
SCSI Activity (1 per SCSI I/O module)
Fibre Channel I/O card status (1 per Fibre I/O module)
Fibre channel link status (2 per Fibre I/O module)
Power supply status (1 per power supply)
Fan Module status (1 per fan module)
Interface
Interface
Interface
Interface
Ultra3 SCSI to Hard Drives
2 Gb Fibre Channel to Hosts
Maximum Number of
Maximum Number of
Maximum Number of
Maximum Number of
Drives
Drives
Drives
Drives
96 SATA hard drives in 8 MSA20 SATA enclosure or 56 SCSI hard drives in
4 MSA30 enclosures
Temperature Range
Temperature Range
Temperature Range
Temperature Range
Operating
Operating
Operating
Operating
50° to 95° F (10° to 35° C) up to 8000'
-22° to 122° F (-30° to 50° C)
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
Operating
Operating
Operating
Operating
10% to 90%
Non-operating
Non-operating
Non-operating
Non-operating
Up to 95%
Input Power Requirements
Input Power Requirements
Input Power Requirements
Input Power Requirements Rated Input Voltage
Rated Input Voltage
Rated Input Voltage
Rated Input Voltage
100 to 240 VAC
Rated Input Frequency
Rated Input Frequency
Rated Input Frequency
Rated Input Frequency
47 to 63 Hz
Rated Input Current
Rated Input Current
Rated Input Current
Rated Input Current
6.4A Max, 1A typical
Input Power
Input Power
Input Power
Input Power (max)
400W Max, 95W typical
The supply will handle 90Vrms - 254 Vrms (100 - 240 V, +6%, -10%)
Frequency is 47 - 63 Hz
NOTE:
NOTE:
NOTE:
NOTE: Input Power and Heat Dissipation specifications are maximum values
and apply to worst-case conditions at full rated power supply load. The
power/heat dissipation for your installation will vary depending on the
equipment configuration.
MSA1500 Controller
MSA1500 Controller
MSA1500 Controller
MSA1500 Controller
Shelf
Shelf
Shelf
Shelf
2U Rack Form Factor
2U Rack Form Factor
2U Rack Form Factor
2U Rack Form Factor
Dimensions
Dimensions
Dimensions
Dimensions (H x W x D)
3.46 x 19.06 x
24.32
Weight
Weight
Weight
Weight
55 lbs
Shipping Packaging
Shipping Packaging
Shipping Packaging
Shipping Packaging
Dimensions
Dimensions
Dimensions
Dimensions (L x W x D)
32.50 x 11.25 x
34.06
Weight
Weight
Weight
Weight (Gross)
68 lbs
SCSI I/O Module
SCSI I/O Module
SCSI I/O Module
SCSI I/O Module
(Positioned in shelf)
Dimensions
Dimensions
Dimensions
Dimensions (H x W x D)
3.2 x.92 x 14.62
Weight
Weight
Weight
Weight
1.01 lbs
Shipping Packaging
Shipping Packaging
Shipping Packaging
Shipping Packaging
Dimensions
Dimensions
Dimensions
Dimensions (H x W x D)
19.88 x 9.06 x 2.76
Weight
Weight
Weight
Weight (Gross)
1.93 lbs
Fibre Channel I/O
Fibre Channel I/O
Fibre Channel I/O
Fibre Channel I/O
Module
Module
Module
Module
(Positioned in shelf)
Dimensions
Dimensions
Dimensions
Dimensions (H x W x D)
3.2 x .92 x 14.62
Weight
Weight
Weight
Weight
.96lbs
Shipping Packaging
Shipping Packaging
Shipping Packaging
Shipping Packaging
Dimensions
Dimensions
Dimensions
Dimensions (H x W x D)
19.88 x 9.0 6 x 2.76
Weight
Weight
Weight
Weight (Gross)
1.87lbs
QuickSpecs
HP StorageWorks 1500 cs Modular Smart Array
HP StorageWorks 1500 cs Modular Smart Array
HP StorageWorks 1500 cs Modular Smart Array
HP StorageWorks 1500 cs Modular Smart Array
Technical Specifications
DA - 11945 Worldwide — Version 10 — September 26, 2005