beautypg.com

Honeywell CHRONOTHERM T8611G User Manual

Page 6

background image

T8611G CHRONOTHERM

®

DELUXE ZONING HEAT PUMP THERMOSTAT

69-1414—2

6

Degree
temperature
display

14

0

Temperature is
displayed in °F

1

Temperature is displayed in
°C

Not Used.

15

Clock format.

16

0

12-hour clock
format.

1

24-hour clock format.

Not Used.

17 and 18

Extended fan
operation in
heating.

19

0

No extended fan
operation after the
call for heat ends.

1

Fan operation is extended
90 seconds after the call for
heat ends.

Extended fan
operation in
cooling.

20

No extended fan
operation after the
call for cool ends.

1

Fan operation is extended
90 seconds after the call for
cool ends.

Not Used.

21 thru 23

Outdoor
temperature
display (models
with OT
terminals).

24

0

No outdoor
temperature is
displayed.

1

Outdoor temperature is
displayed. Needs a
C7089B1000 Outdoor
Temperature Sensor to
operate.

Not Used.

25 thru 28

O/B terminal
energized in
heating or
cooling.

29

0

O/B terminal
energized for
reversing valve in
cooling.

1

O/B terminal energized for
reversing valve in heating

Deadband

30

3

Heating and
cooling setpoints
can be set no
closer than 3°F
(1.5°C).

2 thru 10 Heating and cooling

setpoints can be set no
closer than the chosen
value:

2—2°F (2°C)
4—4°F (2°C)
5—5°F (2.5°C)
6—6°F (3°C)
7—7°F (3.5°C)
8—8°F (4°C)
9—9°F (4.5°C)
10—10°F (5°C)

Not Used.

31 thru 32

Minimum off
time for the
compressor.

33

5

5 minute minimum
off time for the
compressor.

0 thru 4

Minimum number of minutes
(0 thru 5) the compressor is
off between calls for the
compressor.

Temperature
range stops in
heating.

34

90

Highest heating
setpoint setting.

40 to 89

Temperature range (1°F
increments) of heating
setpoint settings.

Temperature
range stops in
cooling.

35

45

Lowest cooling
setpoint setting.

46 to 99

Temperature range (1°F
increments) of cooling
setpoint settings.

System on
indicator
(flame=heat,
snowflake=
cool) is
displayed.

36

0

LCD on symbol is
displayed when
system is
energized

1

Icons in display are
disabled.

Table 4. Thermostat Installer Setup Options. (Continued)

Select

Installer Setup

Number (Press

Time

key to

change)

Factory Setting

Other Choices

(Press or key to change)

Actual

Setting

Display

Description

Display

Description