Installer setup – Honeywell CHRONOTHERM T8611G User Manual
Page 5
T8611G CHRONOTHERM
®
DELUXE ZONING HEAT PUMP THERMOSTAT
5
69-1414—2
INSTALLER SETUP
The Installer Setup is used to customize the thermostat
to specific systems. Some of the options include
temperature display, changeover, and outdoor
temperature display. Installer Setup numbers are listed in
Table 4. The table includes all the configuration options
and the factory settings for the T8611.
Table 3. Default Program Settings.
A combination of key presses are required to use the
Installer Setup feature:
— To enter the installer setup, press and hold the
information i key with the increase and decrease
keys until the first number is displayed. All display
segments appear for approximately three seconds
before the number is displayed. See Fig. 9 and 10.
— To advance to the next Installer Setup, press the
Time
∆ key.
— To change a setting, use the increase or
decrease key.
— To scroll the Installer Setup numbers backward, press
the Time
∇ key.
— To exit the Installer Setup, press Run Program.
Fig. 9. Display of all LCD segments.
Fig. 10. Display of Installer Setup
number and setting.
IMPORTANT
Only configurable numbers are shown on the
device. Review Table 4 factory-settings and
mark any desired changes in the Actual Setting
column. When Installer Setup is complete,
review the settings to confirm that they match
the system.
Period
Time
Heat
Setpoint
Cool
Setpoint
Fan
Setting
Wake
6:00 AM
70°F
(21°C)
78°F
(25.5°C)
Auto
Leave
8:00AM
62°F
(16.5°C)
85°F
(29.5°C)
Auto
Return
5:00 PM
70°F
(20°C)
78°F
(25.5°C)
Auto
Sleep
10:00 PM
62°F
(16.5°C)
82°F
(28°C)
Auto
M14559
Aux Ht
Set Day/Time
Set Program
Mon
Wake Leave Return
Sleep
Outdoor
Room
Filter
Wait
System
Fan
Em Heat
On
Auto
Off
Cool
Auto
AM
PM
Hold for
Heat
Cool
Repl Batt
Recovery
DST
Tue Wed Thu Fri Sat Sun
Days
Temporary Setting
Em Ht
M14618
INSTALLER SETUP
NUMBER DISPLAY
(COLUMN 2 OF TABLE 3)
FACTORY SETTING OR OTHER
CHOICE DISPLAY (COLUMN 3
OR 5 OF TABLE 3)
Table 4. Thermostat Installer Setup Options.
Select
Installer Setup
Number (Press
Time
∆ key to
change)
Factory Setting
Other Choices
(Press or key to change)
Actual
Setting
Display
Description
Display
Description
Not Used.
1 thru 4
—
—
—
—
—
Heating cycle
rate
a
5
6
Stage 2
3 or 9
3—3 cph (factory setting for
first stage of heat)
6—6 cph used for second
stage of heat
9—9 cph used for electric
heat
6 (Not Used).
—
—
—
—
7
9
Emergency heat
3 or 6
Not Used.
8 thru 11
—
—
—
—
—
System setting
adjustment
12
1
Manual
changeover
0 or 2
0—Auto changeover.
2—Fixed auto changeover.
Adaptive
Intelligent
Recovery™
control.
13
0
Adaptive Intelligent
Recovery™
control is activated
(system starts
early so setpoint is
reached by start of
program period).
1
Conventional recovery
(system starts recovery at
programmed time).
—