Mounting thermostat, T8611g chronotherm, Deluxe zoning heat pump thermostat – Honeywell CHRONOTHERM T8611G User Manual
Page 3
T8611G CHRONOTHERM
®
DELUXE ZONING HEAT PUMP THERMOSTAT
3
69-1414—2
Fig. 4. Typical wiring diagram for T8611G on TotalZone® Control Panel.
Fig. 5. Correct wiring technique.
Mounting Thermostat
1. Engage tabs at the top of the thermostat and wall-
plate. See Fig. 6. Be sure to align subbase pins to
avoid damage to the thermostat.
2. Press lower edge of case to close and latch.
NOTE: To remove the thermostat from the wall, first pull
out at the bottom of the thermostat; remove top
last.
Fig. 6. Mounting thermostat on wallplate.
NORMALLY, WIRE E ON THERMOSTAT TO W1/E ON PANEL;
ALTERNATIVELY, INSTALL JUMPER FROM E TO Y ON
THERMOSTAT AND OMIT WIRE TO W1/E ON PANEL.
CONNECT O/B JUMPER ON TZ-4 PANEL WHEN O/B TERMINAL ON
THERMOSTAT IS CONFIGURED AS O.
CONNECT THE OC TERMINALS ONLY IF THE ZONE-A-LONE UNOCCUPIED
FEATURE IS DESIRED. SEE TZ-4 INSTALLER INSTRUCTIONS FOR EXPLANATION.
TZ-4
THERMOSTAT
CONNECTORS
1
2
3
2
C
OC
OC
E
Y
G
O/B
R
W2
L
OT
OT
OC
OC
C7089B OUTDOOR
TEMPERATURE
SENSOR (OPTIONAL)
M20932
1
3
M4826
FOR WRAPAROUND
INSERTION STRIP
7/16 IN. (11 MM).
FOR STRAIGHT INSERTION
STRIP 5/16 IN. (8 MM).
M14634
PRESS LOWER
EDGE OF CASE
TO LATCH.
ENGAGE TABS
AT TOP OF
THERMOSTAT
AND WALLPLATE.
A.
B.