Henny Penny OEA User Manual
Page 9

Model OFE/OFG/OEA/OGA-341, 342
Special Programming is used to set the items below:
Fahrenheit or Celsius
Initialize System
Lock or Unlock Controls
Fryer Type – Open or Pressure
Heat Source – Electric; Gas w/standing pilot;
Gas w/electronic ignition; Gas-Induced Draft
Vat Type - Split or Full Vat (frypot)
Oil Type - Solid or Liquid
1.
To enter Special Programming, turn off power switch
(either side). Press and hold and turn the power
switch back on.
2.
“SPEC” “PROG” followed by, “DEG” “°F” or “°C”. Use
to choose “°F” or “°C”.
3.
Press
and “INIT” shows in the display.
Press and hold the right
and display shows “In-3”,
“In-2”, “In-1” followed by “Init Sys” “DONE DONE”. The
controls now are reset to factory parameters, the time set to
0:00 and temperature 190°F or 88°C.
4.
Press
and “LOCK” or “UNLOCK” shows in the
displays. Use
to choose “LOCK” or
“UNLOCK”.
5.
Press
and “FRYR” shows in left display and the right
display should show “OPEN”. Use to change
from “PRES” to “OPEN” if needed.
6.
Press
and “FRYR” shows in the display. Use
to change the fryer type: “ELEC” for electric
models; “GAS” for units with standing pilot; SSI for units
with solid state ignition; IDG for units with induced draft gas
burners.
7.
Press
and “VAT” shows in the display. Use
to choose “SPLIT” or FULL” vat (frypot) type.
8.
Press
and “MELT” and “Solid” or “LIQD” shows in
the displays. Use
to choose “Solid”, if using
solid shortening, or “LIQD”, if using liquid shortening.
9.
Press and hold
to exit Special Programming at any
time.
1209
3-9
3-6. C1000 SPECIAL
PROGRAMMING