III. Cleaning and Maintenance

WARNING

CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are
securely in place after any cleaning or maintenance is done to the unit. Make
sure that none have fallen into the storage bin.

A. Cleaning and Sanitizing Instructions

Hoshizaki recommends cleaning and sanitizing this unit at least twice a year. More
frequent cleaning and sanitizing, however, may be required in some existing water
conditions.

WARNING

1. To prevent injury to individuals and damage to the icemaker, do not use

ammonia type cleaners.

2. Carefully follow any instructions provided with the bottles of cleaning and

sanitizing solution.

3. Always wear liquid-proof gloves and goggles to prevent the cleaning and

sanitizing solutions from coming into contact with skin or eyes.

4. After cleaning and sanitizing, do not use ice made from the cleaning and

sanitizing solutions. Be careful not to leave any solution on the parts or in the
storage bin.

Fig. 9

Spout B

Spout A

Extruding Head

Agitating Motors

Dispensing Motor

Agitators

Dispensing

Auger

Power Switch

Control Switch

Dispense Mode Switch

Reservoir

Bin Control Assembly

Storage Bin Cover

Spout Cover

Evaporator Assembly

Safety Switch

Optical Sensors (-OS)

Float Switch

Ice Guide

Drain Pipe Holder

Drain Pipe