Iii. cleaning and maintenance, A. cleaning and sanitizing instructions, Iii. cleaning and maintenance warning – Hoshizaki DCM-750BWH(-OS) User Manual
Page 25: Warning, Fig. 9

25
III. Cleaning and Maintenance
WARNING
CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are
securely in place after any cleaning or maintenance is done to the unit. Make
sure that none have fallen into the storage bin.
A. Cleaning and Sanitizing Instructions
Hoshizaki recommends cleaning and sanitizing this unit at least twice a year. More
frequent cleaning and sanitizing, however, may be required in some existing water
conditions.
WARNING
1. To prevent injury to individuals and damage to the icemaker, do not use
ammonia type cleaners.
2. Carefully follow any instructions provided with the bottles of cleaning and
sanitizing solution.
3. Always wear liquid-proof gloves and goggles to prevent the cleaning and
sanitizing solutions from coming into contact with skin or eyes.
4. After cleaning and sanitizing, do not use ice made from the cleaning and
sanitizing solutions. Be careful not to leave any solution on the parts or in the
storage bin.
Fig. 9
Spout B
Spout A
Extruding Head
Agitating Motors
Dispensing Motor
Agitators
Dispensing
Auger
Power Switch
Control Switch
Dispense Mode Switch
Reservoir
Bin Control Assembly
Storage Bin Cover
Spout Cover
Evaporator Assembly
Safety Switch
Optical Sensors (-OS)
Float Switch
Ice Guide
Drain Pipe Holder
Drain Pipe