CL36D AND CR36D INSTALLATION INSTRUCTIONS

WARNING!

Never install a single wall slip section or smoke-pipe in a chase structure. The higher temperature of this single

wall pipe may radiate sufficient heat to combustible chase materials to cause a fire.

WARNING!

Detailed instructions for installation of the chase top, storm collar and termination cap are packaged with these

parts. To avoid danger of fire, all instructions must be strictly followed, including the provision of air space clearance

between chimney system and enclosure. To protect against the effects of corrosion on those parts exposed to the

weather, we recommend that the chase top and termination cap be painted with a rust-resistant paint.

Figure 24 - Installing an ST375 Square

Termination Cap

c. For installations utilizing an ST375 square

termination cap the last chimney section must

not be more than 4½” below the chase top. See

Figure 24.

d. For installation utilizing a TS345/TS345P Square

Termination Cap, the uppermost chimney section

must not be more than 3” below the chase top.

See Figure 25.

e. Attach the chase top (CT35) to the top of the

chase.

f.

Install the termination cap, following the

instructions provided with it.

Figure 25 - Installing a TS345/TS345P

Square Termination Cap