beautypg.com

Cl36d and cr36d installation instructions, Framing the fireplace, Clearances – Hearth and Home Technologies CL36D User Manual

Page 11

background image

02-02

11

12538 Rev D

CL36D AND CR36D INSTALLATION INSTRUCTIONS

Figure 4 - Framing the Fireplace

WARNING!

Do not apply combustible finishing materials over any part of the black face of this fireplace or a structure fire

may result. The black metal fireplace front may only be covered with noncombustible materials such as ce-

ramic tile, brick or stone. Do not cover or block any cooling air slots. Do not cover any portion of the opening to

the fireplace that would prevent the installation of an authorized glass door.

2. Framing the Fireplace

The CL36D/CR36D fireplace will fit a framed opening of 44” or 36

5

/

8

” wide (depending on where the outside air is

located) x 42½” tall. The finished cavity depth must be no less than 22½”.
Figure 4 shows a typical framing (using 2 x 4 lumber) of the fireplace, assuming combustible materials are used.

All required clearances to combustibles around the fireplace must be adhered to. Any framing across the top of the

fireplace must be above the level of the top standoffs. Chimney sections at any level require a 2” minimum air

space clearance between the framing and chimney section.

CLEARANCES!

A minimum ½” air clearance must be

maintained at the back and side of the

fireplace assembly.
Chimney sections at any level require a

2” minimum air space clearance

between the framing and chimney

section.