Honeywell HCE 60 User Manual
Page 48
Appendix
46
Help with problems
Problem
Cause/Solution
LED does not
illuminate when power
plug is plugged in.
Mains voltage not connected.
►
Check voltage of electrical outlet.
►
Check fuse at storey controller.
LEDs 1 through 8 of
the zones do not
illuminate red continu-
ously during start-up.
The setpoint adjuster cannot be assigned.
►
Check whether batteries in setpoint ad-
juster are inserted properly.
►
Check wireless connection.
LEDs 1 through 8 of
the zones do not
illuminate green con-
tinuously during start-
up.
The room name cannot be assigned.
►
Check whether Hometronic Manager is
installed.
►
Check whether or not a room name is
assigned to zone.
►
Reassign zone if applicable.
Not all rooms are
warmed/cooled.
►
Check heating and inlet temperature.
►
Check adaptation to thermal actuator (see
Page 15).
►
Check fuse of storey controller.
If fuse is defective:
►
Check actuators for short circuit.