RASMan Configuration File
RASMan application settings are stored in the Settings section of
\IPSM\RASMan.exm
(see page 2-2) to change the values in the RASMan.exm file.
Key
Description
Default
Value
Available Values
AudioNotification
Enable and disable audio
notifications on connecting and
disconnecting.
1
0=Disable
1=Enable
AutoConnectOnDock
Connects and disconnects RASMan
when the terminal is docked and
removed from the communication
peripheral.
1
0=Disabled; RASMan connection
must be launched manually
when the terminal is docked.
1=RASMan connects on an AC
power event.
2=RASMan connects on RS-232/
USB connection.
AutoConnectOnStart
up
Controls the automatic connection
when RASMan is started.
Note: RASMan attempts to connect
only if the device is docked
and AC power is detected.
1
0=Disabled; the PPP connection
is not established when
RASMan is started.
1=Enabled; the PPP connection
is established when RASMAN
is started.
Connectoid
Indicates the connection RASMan
should use.
`USB
Connectio
n
`USB Connection
`115200 Default
`19200 Default
`38400 Default
`57600 Default
Note: These values must be
typed in exactly as they
appear here.
CommandLine
Command to execute on a
successful connection.
Empty
Leave empty if no action is
required.
CommandArgs
Command arguments for the
CommandLine setting.
Empty
Leave empty if no action is
required.
ConnectDelay
Specifies the amount of time to wait
before establishing the PPP
connection after RASMan is
started.
2000
Enter values in milliseconds.
Debug
Enables and disables the creation
of a debug log file.
0
0=Disabled; no log file
1=Enabled; Creates a log file of
RASMan activity in the
\IPSM
folder.
DisableActiveSync
Disables the ActiveSync connection
when RASMan is running.
1
0=Disabled; ActiveSync runs
while RASMan is running.
1=Enabled; the ActiveSync
connection is disabled while
RASMan is running.