Dimensions

Dimensions

Dimensions

Dimensions (H x W x D)
(with bezel)

1.69 x 17.64 x 27.5 in (4.30 x 44.80 x 69.85 cm)

Weight

Weight

Weight

Weight
(approximate)

Maximum
(two hard drives, power
supply, and processor
installed)

32.40 lb (14.70kg)

Minimum
(one hard drive, power
supply, and processor
installed)

31.00lb (14.00kg)

Input Requirements

Input Requirements

Input Requirements

Input Requirements
(per power supply)

Range Line Voltage

90 - 132 VAC,
180 - 264 VAC

Rated Input Current

6 A (at 100 VAC),
3 A (at 200 VAC)

Rated Input Frequency

47 to 63 Hz

Rated Input Power

<500W @115/230 VRMS (For frequency only)

BTU Rating

BTU Rating

BTU Rating

BTU Rating

Maximum

1194 BTU/hr (at 115/230 VRMS)

Power Specifications

Power Specifications

Power Specifications

Power Specifications

To review typical system power ratings use the Power Calculator which is
available via the online tool located at URL:

http://h30099.www3.hp.com/configurator/calc/Power%
20Calculator%20Catalog.xls

- Click on the system of interest. Example: DL120 G5
- Follow the instructions of the next screens.

Power Supply Output

Power Supply Output

Power Supply Output

Power Supply Output
(per power supply)

Rated Steady-State Power 350 W (at 115/230 VRMS),

350 W (at 115/230 VRMS)

Maximum Peak Power

350 W (at 115/230 VRMS),
350 W (at 115/230 VRMS)

System Inlet Temperature

System Inlet Temperature

System Inlet Temperature

System Inlet Temperature Operating

10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 300 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).

Non-operating

-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).

Relative Humidity

Relative Humidity

Relative Humidity

Relative Humidity
(non-condensing)

Operating

10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.

Non-operating

5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.

QuickSpecs

HP ProLiant DL120 Generation 5 (G5)

HP ProLiant DL120 Generation 5 (G5)

HP ProLiant DL120 Generation 5 (G5)

HP ProLiant DL120 Generation 5 (G5)

Technical Specifications