B. Facing Material

Figure 11.3 Noncombustible Facing

Fire Risk.
Do NOT obstruct air inlet or outlet grilles.
Do NOT modify grilles.
• Modifying or covering grilles could cause

temperature rise and fi re hazard.

Finishing materials must not interfere with:
• Air fl ow through grilles or louvers.
• Operation of louvers or doors.
• Access for service.

41 in.

39-3/8 in.

NON-COMBUSTIBLE ZONE (Shaded areas)

A

To p V ie w

IN T E R IO R W A L L

F IR E P L A C E

O P E N IN G

B

M A N T E L L E G O R W A L L P R O J E C T IO N S

Note: All
measurements
in inches.

MEASUREMENTS FROM

TOP EDGE OF THE OPENING

5

10

11

12

2-1/2

13

14

15

16

17

18

19

32

TO CEILING

9

10

11

12

8

7

6

5

4

3

25

18

Note: Measurement is taken from top of the
opening, NOT the top of the fi replace.

If

A

minimum is ____, then

B

maximum is_____.

A

Inches

2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16

Millimeters

62

87

113

138

164

189

B

Inches

1

2

3

4

5

Millimeters

25

51

76

102

127

A. Mantel Projections

Figure 11.1 shows the minimum vertical and correspond-
ing maximum horizontal dimensions of appliance mantels
or other combustible projections above the top front edge
of the appliance.

11

11

Finishing

Fire Risk.

Finish all edges and fronts to clearances and
specifi cations listed in manual.

• Do NOT overlap combustible materials onto appliance

front.

The appliance front may only be covered with

noncombustible materials. The bottom one inch of the
appliance front is exempt and may be covered with either
non-combustible or combustible materials.

• Install combustible materials only up to specified

clearances on top, front and side.

• Seal joints between the fi nished wall and appliance top

and sides using only a 300º F minimum sealant.

Risk of Fire

• Non-combustible clearances MUST be

maintained.

• Sheetrock, wood or other combustibles must

NOT be used as sheathing or facing in the
non-combustible zone.

• See Section 11 for proper clearances.

• See Section 1 for combustible/non-

combustible defi nitions.

WARNING

WARNING

Figure 11.2 Mantel leg or Wall projections

(Acceptable on both sides of opening.)

Figure 11.1 Clearances to mantels or other combustibles

above appliance

WARNING