Problem

Possible Cause

Remedy

[3]Other.

a) Ice Cube Guide

1. Out of position.

1. Place in position.

b) Thermostatic Bin

Control

1. Bulb out of position.

1. Place in position.

2. Bad contacts.

2. See "IV.C. Bin Control

Check."

3. Low Ice Production

Problem

Possible Cause

Remedy

[1] Freeze cycle time is

long.

a) Inlet Water Valve

1. Diaphragm does not

close.

1. Check for water leaks with

icemaker off.

b) Float Switch

1. Float switch does

not move freely or
defective switch.

1. Clean or replace. See "IV.

D. Float Switch Check and
Cleaning."

c) Evaporator

1. Scaled up.

1. Clean.

2. Damaged.

2. Replace.

d) Spray Tubes

1. Dirty.

1. Clean.

2. Out of position.

2. Place in position.

e) Water Pump

1. RPM too slow.

1. See chart 1.[5].

f) Condenser (except

water-cooled model)

1. Air filter or condenser

clogged.

1. Clean.

g) Refrigerant Charge

1. Low charge.

1. Check for leaks. Recover,

repair, evacuate, and
recharge.

h) Hot Gas Valve

1. Open.

1. Check and replace.

i) Expansion Valve

1. Bulb loose.

1. Secure bulb.

2. Operating erratically.

2. Check and replace.

j) Compressor

1. Erratic or off.

1. See chart 1.[3].

k) Condenser Water

(water-cooled model)

1. Water regulating valve

set too high.

1. Adjust or replace. See

"V.J. Adjustment of Water
Regulating Valve."

2. Condenser water

pressure too low.

2. Check and get

recommended pressure.

3. Water temperature out

of specification.

3. Correct to specification.

l) Liquid Line Valve

1. Erratic, sticking.

1. Check and replace.

m)Headmaster (C.P.R.)

(remote condenser
unit)

1. Bypassing.

1. Replace.

n) Control Board

1. Float switch

connection loose (K5).

1. Check and reconnect.

2. Defective.

2. See "IV.B. Control Board

Check."