C. Performance Data

1. KM-1301SAH (air-cooled)

Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in

bold

should be used for reference only.

2. We reserve the right to make changes in specifications and design without prior

notice.

70/21

1329

603

1281

581

1188

539

80/27

1292

586

1217

552

1109

503

90/32

1281

581

1164

528

1060

481

lbs./day kg./day

100/38

1253

568

1140

517

965

438

70/21
80/27
90/32

watts

100/38

70/21

605

2.29

481

1.82

429

1.62

80/27

510

1.93

318

1.21

331

1.25

90/32

481

1.82

183

0.69

167

0.63

gal./day m

3

/day

100/38

345

1.30

179

0.68

152

0.58

70/21
80/27
90/32

min.

100/38

70/21
80/27
90/32

min.

100/38

70/21

255

17.9

273

19.2

298

20.9

80/27

269

18.9

297

20.9

321

22.6

90/32

273

19.2

317

22.3

342

24.0

PSIG kg/cm

2

G

100/38

278

19.5

323

22.7

365

25.7

70/21

50

3.5

50

3.5

53

3.8

80/27

50

3.5

50

3.5

55

3.9

90/32

50

3.5

50

3.5

55

3.8

PSIG kg/cm

2

G

100/38

52

3.6

51

3.6

59

4.1

20,300 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

32

36

32
33

35

32
34

2.1

4.7

3.1

3.9
2.9
2.1

4.1

31

APPROXIMATE ICE

PRODUCTION PER 24 HR.

APPROXIMATE ELECTRIC

CONSUMPTION

APPROXIMATE WATER

CONSUMPTION PER 24 HR.

FREEZING CYCLE TIME

WATER TEMP. (ºF/ºC)

AMBIENT TEMP.

(ºF/ºC)

50/10

70/21

90/32

2193

2166
2174
2180
2197

2160
2164
2166

35
37
38
41

2222
2257
2253
2320

HARVEST CYCLE TIME

HEAD PRESSURE

3.7
3.1

3.9

2.1
2.1

TOTAL HEAT OF REJECTION FROM CONDENSER

SUCTION PRESSURE

ENG.F-011.1.0205