beautypg.com

F. shutdown notice, Important, Warning – Hoshizaki JWE-620UA-6B User Manual

Page 74

background image

69

F. Shutdown

NOTICE

If there is a possibility that the ambient
temperature may fall below 32°F (0°
C) and freeze the unit, be sure to drain
the unit. The water supply line could be
damaged and leak water, resulting in
damage to the surrounding property.

To drain out the water heater, close the
water supply line shut-off valve, and
open the drain valve and water supply
valve.

1) Press the “ON/OFF” button on the operation panel. The display and lamps go off.
2) Open the cover in the front panel, then move the power switch (GFCI) to the “OFF”

position.

3) Turn off the water heater.
4) Turn off the gas and water supplies.

IMPORTANT

To operate the water heater, follow its instruction manual.

5) Tilt back the rack rail.

IMPORTANT

The rack rail may fall down if tilted more than 10°. Do not hang anything from it
or hit it hard.

6) Pull out the drain pipe to drain water from the

wash tank.

WARNING

When pulling out the drain pipe, be careful not to touch the wash water. It may
cause burns or skin irritation. Turn the drain pipe if it is hard to pull out.

Water Heater

Gas Supply Line

Shut-off Valve

Water Supply Line

Shut-off Valve

Water

Gas

Water Supply Valve

Drain Valve

Dishwasher