Hoshizaki JWE-620UA-6B User Manual
Page 64

59
K. Removal and Replacement of Flush Pipe
1) Remove the rack rails, upper/lower wash and rinse spray arms, tank fi lters, overfl ow
pipe, and separator.
2) Remove the rack guide.
3) Remove the band.
4) Remove the upper and lower headers.
5) Unscrew the joint to the pump discharge outlet, then remove the fl ush pipe.
6) To replace, reverse the above procedure.
Note: Be sure to use new O-rings and gaskets.
7) Make a trial run, and check for water leaks.