22

21

Total Operation Cycles Before
Alert

10 to 990 cycles

1 to 99

2
(20 cycles)

22

Display Hold Function

ON: stays on
OFF: goes off after 10 minutes

on or oF

oF

23

Power Supply Lock Function ON: "Ch" keeps fl ashing until

electrode is turned off
OFF: "Ch" goes off when "ON/
OFF" button is switched off

on or oF

oF

24

N/A

25

N/A

26

through

30

Error Log

Note: To erase the log, press
and hold the up and down
buttons for 3 seconds with one
of the error codes displayed.
The unit beeps once and the
entire log clears.

NA

Most Recent
Errors
26 is most
recent.
"--" is displayed
if the log is
empty.

NA

8. Temperature Display

• Indicates the average water temperature read by the wash tank or internal booster tank

thermistor. Indicates wash tank water temperature in wash cycle, rinse (internal booster tank)
water temperature in rinse cycle. Press the down button to indicate rinse (internal booster
tank) water temperature instead of wash tank water temperature while the dishwasher is in
"READY" mode. To change the normal temperature display to the rinse (internal booster
tank) water temperature, see "Water Temperature Display" (service menu item 12) in "II.
D.7.b) Service Menu Chart."

• The temperature display range is 32°F to 199°F (0°C to 99°C). To change the display

scale, see "Temperature Display Scale" (service menu item 13) in "II.D.7.b) Service Menu
Chart."

• The temperature display updates every 30 seconds for the wash tank and every 5 seconds

for the internal booster tank.