Chapter 4 Explanation of Functions
4 - 1
29
(xii) 0B command: This command recalculates the constants set in the inverter.
This command must be issued when the base frequency or the setting of parameter "H***" has been
changed for the RS485 communication.
- Transmission frame
Frame format
STX Station
No.
Command BCC
CR
Description
Data
size
Setting
STX
Control code (Start of TeXt)
1 byte
STX (0x02)
Station No.
Station number of control-target
inverter
2 bytes
01 to 32
Command
Command to be transmitted
2 bytes
0B
BCC
Block check code
2 bytes
XOR of the items from "Station No." to "Data."
See Item (3) of this section.
CR
Control code (Carriage Return)
1 byte
CR (0x0D)
- Response frame
Positive response: See Item (2)-(i) of this section.
Negative response: See Item (2)-(ii) of this section.
- C 7D (92 pages)
- DV18DMR (96 pages)
- DH 40FA (34 pages)
- SERIES D (28 pages)
- 231580 (34 pages)
- 206700 (24 pages)
- WH14DM OM (76 pages)
- DS 12DVF2 (4 pages)
- SJ-PB(T) (35 pages)
- NT 65M (4 pages)
- DH 40MRY (62 pages)
- RTX 900 (34 pages)
- DH 24DV (88 pages)
- FDS 9DVA (60 pages)
- L100 300 (16 pages)
- G13SE2 (52 pages)
- N 5008AC (42 pages)
- L300P (264 pages)
- DH 38YE (64 pages)
- CONVENTION 14 (305 pages)
- DS 14DVB (4 pages)
- H 45MR (52 pages)
- WH9DM2 (108 pages)
- B 16RM (64 pages)
- DH 24PD (28 pages)
- L300P Series (76 pages)
- W 8VB (52 pages)
- SJ2-CO (35 pages)
- CR 10DL (56 pages)
- DS18DVB2 (30 pages)
- WR 9DM (98 pages)
- CR 18DV (80 pages)
- 24PD (58 pages)
- SJ100 (214 pages)
- G 18MR (52 pages)
- 308640 (28 pages)
- DH 45MR (68 pages)
- NR90AA (48 pages)
- L100 (163 pages)
- 232624 (24 pages)
- 288466 (14 pages)
- SJ-DG (20 pages)
- C6DD (22 pages)
- VARIABLE SPEED DV 18DV (68 pages)