Harbor Freight Tools CENTRAL PNEAMATIC 95386 User Manual
Page 13
Page 13
For technical questions, please call 1-800-444-3353.
SKU 95386
Turn the Drain Valve, at the bottom
17.
of the Tank, one full turn counter
clockwise, to release any built-
up moisture and the internal tank
pressure. Close the valve after
moisture has drained out. Do not
remove the Drain Valve.
Clean, then store the Air Compressor
18.
indoors.
emergency depressurization
If it is necessary to quickly
depressurize the Compressor, turn
OFF the Compressor by pushing
down on the On/Off Button. Then,
pull on the ring on the Safety Valve
(56) to quickly release stored air
pressure.
automatic Shut-off System
Figure 6
Reset
Button
(20)
1. If the Compressor automatically shuts
off:
Disconnect all tools.
a.
Push down on the ON/OFF Power
b.
Button.
Wait until the Compressor cools
c.
down (about 10 minutes);
Press the Reset Button (20) to start
d.
the compressor;
Pull up on the ON/OFF Power
e.
Button.
Resume operation.
f.
Possible causes of repeated
2.
automatic shut off of the compressor
are:
Using an extension cord that is too
a.
long or narrow;
An air leak or open hose causing the
b.
compressor to cycle too often and
build up heat.
Correct any issues before further use
3.
to avoid damage to the compressor.