HMI-103/105

2-13. CONTACTOR

1. Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move

power switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.

2. Remove the pans and pan supports from unit.

3. Remove the four screws securing the access panel

and remove panel.

To avoid electrical shock, make connections before apply-

ing power, take reading, and remove power before re-

moving meter leads. The following checks are performed

with wall circuit breaker closed and main power switch

in the ON position.

4. With power reapplied, set infi nite regulator to its highest setting.

5. Perform checks on the contactor as follows:

Test

Points

Results

From terminal 27 to 28 The voltage should read the

From terminal 28 to 29 same at each terminal and

From terminal 27 to 29 should correspond to voltage

rating stated on data plate.

6. Remove electrical power supplied to unit and remove and

label wires from contactor.

7. Perform checks on contactor as follows:

Test

Points

Results

From 23 to 29

open circuit

From 24 to 28

open circuit

From 22 to 26

open circuit

ohm reading 415

8. If contactor is defective, remove screws securing contactor

and remove contactor from unit.

9. Install new contactor.

2-8

203

Step 3

Steps 5 and 7

Step 6

Step 8