2-7. POWER SWITCH (Continued) 4. Check across top and bottom terminals for continuity. With
the switch in the ON position, the circuit should be closed.
If not, replace switch by following the next steps.
5. Push in on the tabs at the ends of the switch and pull switch
out from front of the control panel.
6. Replace with new switch.
2-8. INFINITE REGULATOR
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Open control panel cover and remove four screws securing
the control panel.
3. Pull control panel out to access back of regulator. Pull and
label wires from regulator.
4. Pull out on regulator knob and remove the knob from front
of control panel.
5. Using a 5/8 wrench unscrew the nut on the front of control
panel, securing the regulator, and remove the regulator.
6. Install new infi nite regulator.
2-4
203
Step 4
Step 5
Step 3
Step 4
Step 5