G L O S S A R Y

HENNY PENNY HOLDING CABINETS


air temperature probe

a round device located inside the cabinet that measures the inside air

temperature and sends that information to the control panel


concentration ring assembly

a metal assembly located in the water pan in the bottom of the unit that

helps keep an even humidity level inside the cabinet


clean water pan setpoint

a preset temperature at which a sensor warns the operator that the water pan

has excessive lime deposits


control panel

the components that control the operating systems of the unit; the panel is

located on the top front surface of the cabinet


deliming agent

a cleaner used to remove lime deposits in the water pan


drain valve

a device that lets the water drain from the water pan into a shallow pan on

the floor; the valve should be closed while the unit is in use if humidity is

desired

float switch

a device that senses low water levels in the water pan


food probe

a sensor located outside the cabinet that, when inserted into the product,

communicates the temperature of the product to the control panel

food probe receptacle

the connection where the food probe is inserted in order to communicate

with the control panel


humidity sensor a device that measures the percentage of humidity inside the cabinet during

use


humidity setting

a preset moisture level at which the cabinet operates; this setting is

programmed at the factory but can be changed in the field


LED

an electronic light on the control panel


minimum holding temperature

the lowest temperature at which a food product can be safely held for

human

consumption


module

the removable top part of the cabinet that contains all of the operating

system


out of water trip point

a preset temperature at which a sensor warns the operator that the water

pan needs refilled