PROBLEM
POSSIBLE CAUSE
REMEDY
[5] No water
a) Water Supply Line
1. Water pressure too low and
1. Check and get
comes from
water level in water tank
recommended pressure.
spray tubes.
too low.
water pump
b) Water Solenoid
1. Dirty mesh filter or orifice
1. Clean.
will not start, or Valve
and water level in water
freeze cycle
tank too low.
time is too
c) Water System
1. Water leaks.
1. Check connections for
short.
water leaks, and replace.
2. Clogged.
2. Clean.
d) Pump Motor
1. Motor winding opened.
1. Replace.
2. Bearing worn out.
2. Replace.
3. Wiring to pump motor
3. Check for loose
connection or open, and
replace.
4. Defective capacitor.
4. Replace.
5. Defective or bound impeller. 5. Replace and clean.
e) Controller Board
1. Defective.
1. See “II.2.[ e ] Checking the
Controller Board.”
[6] Fan motor will
a) Fan Motor
1. Motor winding opened.
1. Replace.
not start, or is
2. Bearing worn out.
2. Replace.
not operating.
3. Wiring to fan motor.
3. Check for loose
connection or open, and
replace.
4. Fan blade bound.
4. Check and replace.
b) Controller Board
1. Defective.
1. See “II.2.[ e ] Checking the
Controller Board.”
[7] All components a) Refrigerant
1. Undercharged.
1. Check for leaks and
run but no ice
recharge.
is produced.
2. Air or moisture trapped.
2. Replace drier, and
recharge.
b) Compressor
1. Defective valve.
1. Replace.
c) Hot Gas Solenoid
1. Continues to open in freeze
1. Check and replace.
Valve
cycle.
d) Water Solenoid
1. Stuck open.
1. Replace.
Valve
2. Diaphragm bleed port
2. Clean or replace
clogged.
diaphragm.