PROBLEM
POSSIBLE CAUSE
REMEDY
l) Controller Board
1. Defective
1. See “II.2[e] Checking the
Controller Board.”
[2] Water
a) Float Switch
1. Connector disconnected.
1. Place in position.
continues to
2. Leads opened or defective
2. Check and replace.
be supplied,
switch.
and the ice-
3. Float does not move freely.
3. Clean or replace.
maker will not
b) Controller Board
1. Defective.
1. Replace.
start.
[3] Compressor
a) Wash Switch
1. “WASH” position.
1. Move to “ICE” position.
will not start
2. Bad contacts.
2. Check and replace.
or operates
b) High Pressure
1. Dirty air filter or
1. Clean.
intermittently
Control
condenser.
2. Ambient or condenser
2. Reduce ambient temp.
water temp. too warm.
3. Refrigerant overcharged.
3. Recharge.
4. Condenser water pressure
4. Check and get
too low or off. [Water-
recommended pressure.
cooled model only].
5. Fan not operating. [Except
5. See chart 1 - [6].
water-cooled model].
6. Refrigerant line or
6. Clean and replace drier.
components plugged.
c) Overload Protector
1. Bad contacts.
1. Check for continuity and
replace.
2. Voltage too low.
2. Increase voltage.
3. Refrigerant overcharged or
3. Recharge.
undercharged.
d) Starter
1. Bad contacts.
1. Check and replace.
2. Coil winding opened.
2. Replace.
e) Start Capacitor
1. Defective.
1. Replace.
f) Magnetic Contactor
1. Bad contacts.
1. Check for continuity and
replace.
2. Coil winding opened.
2. Replace.
g) Compressor
1. Wiring to compressor.
1. Check for loose
connection or open, and
replace.
2. Defective.
2. Replace.
3. Protector tripped.
3. Reduce temperature.
h) Controller board
1. Defective.
1. See “II.2.[ e ] Checking the
Controller Board.”
[4] Water
a) Water Solenoid
1. Diaphragm does not close.
1. Check for water leaks
continues to
Valve
with icemaker off.
be supplied in
b) Controller Board
1. Defective.
1. See “II.2.[ e ] Checking the
freeze cycle.
Controller Board.”