3) Drain Timer

The drain timer is factory-adjusted, and no adjustment is required.

SETTING

TIME

Dip Switch

Dip Switch

No. 3

No. 4

T1

T2

OFF

OFF

10 seconds

150 seconds

ON

OFF

10 seconds

180 seconds

OFF

ON

10 seconds

120 seconds

ON

ON

20 seconds

180 seconds

T1: Time to drain the water tank
T2: Time to restrain defrost completion

4) Drain Counter

CAUTION

Do not adjust the drain counter, or the evaporator may freeze up.

The drain counter is factory-adjusted to drain the water tank every 10 cycles, and no
adjustment is required. However, where water quality is bad and the icemaker needs a
pump drain more often, the drain counter can be adjusted as shown in the table below:

SETTING

FREQUENCY

Dip Switch

Dip Switch

No. 5

No. 6

OFF

OFF

every cycle

ON

OFF

every 2 cycles

OFF

ON

every 5 cycles

ON

ON

every 10 cycles