beautypg.com

B. install fireplace & chimney, C. install chase top – Hearth and Home Technologies BIR42 User Manual

Page 32

background image

32

Slope Downward
(1/4 in. per foot
minimum)

Turn-down

Drip Edge

Chase

2 in. (51 mm) Collar
on Chase Top

.018 (26 ga) min.
Galvanized
Chase Top

Figure 9.3 Chase Top Construction

B. Install Fireplace & Chimney

Install as per Sections 7 and 8.

Heatilator • Birmingham BIR42 • 4059-308 Rev E • 08/08

C. Install Chase Top

• You MUST use a chase top in a chase installation. Chase

tops are available from your Heatilator dealer or may be
fi eld constructed.

• Include a turndown and drip edge to prevent water from

seeping into the chase.

• Include a 2 in. (51 mm) soldered, caulked or spun collar

around pipe opening to keep water out.

• Provide a 1/8 in. (3 mm) gap around the fl ue pipe.
• Slope the chase top downward away from the opening.

CAUTION! DO NOT caulk the pipe to the chase top collar.

• Caulk all seams to prevent leaks.
• Refer to Figure 9.3.