E. install metal roof flashing, Caulk pipe flashing – Hearth and Home Technologies IDV4833ILH User Manual
Page 34
Heatilator • ICON DV-IDV Series • 4042-575 • Rev K • 11/08
34
D. Disassemble Vent Sections
• Rotate either section (see Figure 10.9) so the seams
on both pipe sections are aligned as shown in Figure
10.10.
• Pull carefully to separate the pieces of pipe.
Figure 10.10 Align and Disassemble Vent Sections
Figure 10.9 Rotate Seams for Disassembly
E. Install Metal Roof Flashing
Note: Skip to Section 10.G. if using the RF4-8.
• See minimum vent heights for various pitched roofs
(Figure 10.11) to determine the length of pipe to extend
through the roof.
• Slide the roof fl ashing over the pipe sections extending
through the roof as shown in Figure 10.12.
Horizontal
overhang
12
X
20 in.
(508 mm)
Lowest
Discharge
Opening
Termination
Cap
Roof Pitch
is X / 12
Vertical
wall
H (min.) - Minimum height
from roof to lowest
discharge opening.
24 in. min.
(610 mm)
Roof Pitch
H (Min.) Ft.
Roof Pitch
H (Min.) Ft.
Flat to 6/12
1.0*
Over 11/12 to 12/12
4.0
Over 6/12 to 7/12
1.25*
Over 12/12 to 14/12
5.0
Over 7/12 to 8/12
1.5*
Over 14/12 to 16/12
6.0
Over 8/12 to 9/12
2.0*
Over 16/12 to 18/12
7.0
Over 9/12 to 10/12
2.5
Over 18/12 to 20/12
7.5
Over 10/12 to 11/12 3.25
Over 20/12 to 21/12
8.0
* 3 ft. minimum in snow regions
Storm Collar
Roof
Flashing
Figure 10.11 Minimum Height From Roof To Lowest Discharge
Opening
Figure 10.12 Install Metal Roof Flashing
NOTICE: Failure to properly caulk the roof fl ashing could
cause water entry.
• Caulk the gap between the roof fl ashing and the outside
diameter of the pipe.
• Caulk the perimeter of the fl ashing where it contacts the
roof surface. See Figure 10.12.
Caulk
Pipe
Flashing