Framing and clearances, A. select appliance location – Hearth and Home Technologies IDV4833ILH User Manual
Page 17

Heatilator • ICON DV-IDV Series • 4042-575 • Rev K • 11/08
17
5
5
Framing and Clearances
A. Select Appliance Location
When selecting a location for the appliance it is important
to consider the required clearances to walls (see Figure
5.1).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access. Due
to high temperatures, the appliance should be located out
of traffi c and away from furniture and draperies.
NOTICE: Illustrations refl ect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Top Vent
One 90° Elbow
Horiz Term
Top Vent
One 90° Elbow
Horiz Term
A
A
D
C
E
B
B
1-1/2 in. (38 mm)
min.
appliance
to combustibles
Alcove
Installation
F
A
Drywall
Figure 5.1 Appliance Locations
Model #
A
B
C
D
E
F
IDV4833I
in.
47-1/2
64-1/4
30-1/2
48-1/2
90-7/8
48
mm
1207
1632
775
1232
2309
1219
IDV6247I
in.
61-1/2
74-1/8
30-1/2
62-1/2
104-7/8
48
mm
1562
1883
775
1588
2665
1219