Setting the real-time clock, Panic keys, Disarmed ready to arm – Honeywell VISTA-20P User Manual
Page 60
SUMMARY OF ARMING MODES
Features for Each Arming Mode
Arming Mode
Exit Delay
Entry Delay
Perimeter Armed
Interior Armed
AWAY Yes Yes
Yes
Yes
STAY Yes Yes
Yes
No
NIGHT-STAY
Yes
Yes
Yes
only those zones
listed in Night-
Stay zone list
INSTANT Yes
No
Yes
No
MAXIMUM Yes
No
Yes
Yes
Panic Keys
There are three Panic keys (A, B, and C) that, if programmed, can be used to manually initiate alarms and
send a report to the central station.
Each key can be programmed for 24-hour Silent, 24-hour Audible, Fire, or Personal Emergency responses.
The programmed Panic response is activated when the appropriate key is pressed for at least 2 seconds.
The Panic keys are identified by the system as follows:
Keys
Displayed as Zone
[A] (
∗∗∗∗/1)
95
[B] (
∗∗∗∗/#)
99
[C] (3/#)
96
IMPORTANT: For a Silent panic function (if programmed) to be of practical value, you must program a
report code for the zone and the system must be connected to a central station.
Setting the Real-Time Clock
Set the time and date by doing the following:
1.
+[#] + [6] [3]
(Security
Code)
Alpha Display:
DISARMED
READY TO ARM
2. Press [
∗] when the time/date is displayed.
A cursor appears under the first digit of the hour.
To move cursor ahead, press [
∗
]. To go back, press [#].
• Enter the 2-digit hour setting.
• Enter the 2-digit minute setting.
• Press [1] for PM or [2] for AM.
• Enter the last two digits of the current year.
• Enter the 2-digit month setting.
• Enter the 2-digit day setting.
3. To exit, press [
∗] when cursor is at the last digit, or wait 10 seconds.
TIME/DATE SAT
04:04PM 10/17/00
Current time display
TIME/DATE SAT
04:04P2000/10/17
Time/date editing display
Installation and Setup Guide
6-6