Audio Alarm Verification
Connections
(AAV, “listen-In”)


• Refer to the connection diagrams below. One diagram shows connections when a

4285/4286 Phone Module is used, the other shows connections when the 4285/4286 is not
used.

• Connections use one of the on-board triggers.

• Set field *91 for AAV and program the appropriate output (output 17 or 18) using *80

Menu mode: select zone type 60 and output action 1 (close for 2 seconds) or action 2 (stay
closed).

• For voice session monitoring, connect an EOLR zone to UVCM module terminals 6 & 7,

and program the zone as zone type 81 (*56 Menu mode).

E.g., Using output 18 for the trigger, program an output function in *80 Menu mode as:
ZT = 60, P = 0, Action = 1, Device = 18

• Suggested AAV Module: ADEMCO UVS (shown) or Eagle 1250

UL

UL installations using the AAV feature must use the ADEMCO UVCM module (part of the

ADEMCO UVS system).

ON

ON

1

2

345

67

8

1

2

345

67

8

12

3

4

5

6

78

9

1

0

1

1

29

30

31

32

33

34

NOTE:
REFER TO UVCM MODULE
INSTRUCTIONS FOR
CONNECTIONS TO AUDIO
SPEAKERS AND MICROPHONE.

UVCM
MODULE

ZONE

TERMINALS

EARTH

GROUND

RED (R)

GREEN (T)

GREY (R)

BROWN (T)

TRIGGER
CONNECTOR

OUTPUT 18

EOL

RING

TIP

OPTIONAL
MONITORING ZONE
CONNECTION
(USE ZONE TYPE 81)

FALLING VOICE TRIG

GND

+12VDC IN

SWITCH

BANK 2

SWITCH

BANK 1

SWITCH BANK 2

SWITCH BANK 1

AUXILIARY

AUDIO LEVEL

ADJUSTMENT

TRIM POT

aa

v_uvcm-003-V0

CONTROL

INCOMING

PHONE LINE

TO

PREMISES

HANDSET

5

1 = ON
2 = ON
3 = OFF
4 = ON
5 = ON
6 = ON
7 = ON
8 = ON

1 = OFF
2 = OFF
3 = OFF
4 = OFF
5 = OFF
6 = OFF
7 = OFF
8 = ON

23

24

25

+12VDC

GND

4

5

21

22

RJ31X

Figure 17a. Connection of AAV Unit When Not Using a 4285/4286 Phone Module

12

3

4

5

6

78

9

1

0

1

1

29

30

31

32

33

34

NOTE:
REFER TO UVCM MODULE
INSTRUCTIONS FOR
CONNECTIONS TO AUDIO
SPEAKERS AND MICROPHONE.

UVCM
MODULE

CONTROL

EARTH

GROUND

RED (R)

GREEN (T)

GREY (R)

BROWN (T)

TRIGGER
CONNECTOR

OUTPUT 18

4285/4286

RING

TIP

FALLING VOICE TRIG

GND

+12VDC IN

SWITCH

BANK 2

SWITCH

BANK 1

SWITCH BANK 2

SWITCH BANK 1

AUXILIARY

AUDIO LEVEL

ADJUSTMENT

TRIM POT

aa

v_uvcm-004-V0

ZONE

TERMINALS

OPTIONAL
MONITORING
ZONE
CONNECTION
(USE ZONE
TYPE 81)

23

24

25

22

21

4

5

INCOMING

PHONE LINE

TO

PREMISES

HANDSET

RJ31X

2

3

4

1

5

1 = ON
2 = ON
3 = OFF
4 = ON
5 = ON
6 = ON
7 = ON
8 = ON

1 = OFF
2 = OFF
3 = OFF
4 = OFF
5 = OFF
6 = OFF
7 = OFF
8 = ON

ON

ON

1

2

345

67

8

1

2

345

67

8

RING

TIP

+12VDC

GND

EOL

Figure 17b. Connection of AAV Unit When Using a 4285 or 4286 Phone Module

Installation and Setup Guide

2-14