Ademco contact id – Honeywell VISTA-20P User Manual
Page 57
Ademco Contact ID
®
The Ademco Contact ID
®
Reporting Format comprises the following:
4-digit or 10-digit subscriber number (depending on format selected).
1-digit event qualifier (“new” or “restore”).
3-digit event code.
2-digit Partition No.
3-digit zone number, user number, or system status number (see the following page).
Ademco Contact ID
®
Reporting takes the following format: CCCC(CCCCCC) Q EEE GG ZZZ
where:
CCCC(CCCCCC) =Customer (subscriber) ID
Q = Event qualifier, where:
E = new event , and R = restore
EEE = Event code (3 hexadecimal digits)
Note: For a complete list of event codes, refer to the central office
receiver manual.
GG = Partition Number (system messages show “00”)
ZZZ = Zone/contact ID number reporting the alarm, or user number for
open/close reports. System status messages (AC Loss, Walk Test, etc.)
contain zeroes in the ZZZ location.
TABLE OF CONTACT ID EVENT CODES
(some event codes may not apply to certain control panels)
Code
Definition
110 Fire
Alarm
121 Duress
122 Alarm,
24-hour
Silent
123
Alarm, 24-hour Audible
131 Alarm,
Perimeter
132 Alarm,
Interior
134 Alarm,
Entry/Exit
135 Alarm,
Day/Night
143
Alarm, Expansion Module
145 ECP
Module
cover
tamper
146 Silent
Burglary
150
Alarm, 24-Hour Auxiliary/Monitor zone
162 Carbon
Monoxide
301 AC
Power
302
Low System Battery/Battery Test Fail
305
System Reset (Log only)
309
Battery Test Failure
321 Bell/Siren
Trouble
333
Trouble, Expansion Mod. Supervision
341
Trouble, ECP Cover Tamper
344 RF
Receiver
Jam
351
Telco Line Fault
353
Long Range Radio Trouble
373
Fire Loop Trouble
374
Exit Error Alarm
380
Global Trouble, Trouble Day/Night
Code Definition
381
RF Sensor Supervision
382
Supervision Auxiliary Wire Zone
383
RF Sensor Tamper
384
RF Sensor Low-battery
393 Clean
Me
401
Disarmed, Armed AWAY, Armed
MAXIMUM
403
Schedule Arm/Disarm AWAY
406
Cancel by User
407
Remote Arm/Disarm (Downloading)
408
Quick Arm AWAY
409
Keyswitch Arm/Disarm AWAY
441 Disarmed/Armed
STAY/INSTANT,
Quick-Arm STAY/INSTANT
442
Keyswitch Arm/Disarm STAY
459 Recent
Closing
570 Bypass
601
Manually Triggered Dialer Test
602
Periodic Test
606
AAV to Follow
607
Walk Test Entered/Exited
623
Event Log 80% Full
625
Real-Time Clock was Changed (log only)
627
Program Mode Entry (log only)
628
Program Mode Exit (log only)
642
Latch Key (log only)
750 -
789
Reserved for Configurable Zone Type
report codes (check with central station
when using these codes)
System Communication
6-3