Detail a – Heat & Glo Fireplace HEAT & GLO Escape-42DV User Manual
Page 42

Heat & Glo • Escape-42DV • 2052-900 Rev. Y • 11/11
42
Figure 12.1 IntelliFire Pilot Ignition (IPI) Wiring Diagram
IPI
VALVE
ORANGE
GREEN
RED
RED
GROUND
PIGTAIL
GREEN
AUX
CONNECTION
FRONT VIEW
REAR VIEW
G Y R
BLACK
BLACK
AC
PLUG
FAN
CONNECTION
ORANGE
BATTERIES
1
2
3
4
5
6
7
8
R Y G
ORANGE
IPI
MODULE
FLAME
SOLENOID
FLAME HIGH/LOW
BLACK
RED
BLACK
RED
RED
BLACK
RED
(MALE/FEMALE)
RED
(FEMALE/MALE)
ADAPTER WIRES
BROWN
BROWN
GROUND
BLACK
BROWN
BROWN
RED
GREEN
YELLOW (HNG)
WHITE (HTL)
BATTERY
IPI PILOT
3V DC
FLAME ON
YELLOW
YELLOW
FAN THERMOSTAT
FACTORY
CONNECTED
TOGETHER
FIREBOX LIGHTS
CONTINUOUS
110VAC
SUPPLY
BLACK
WHITE
GROUND
HOT
FA
N
TRANS
REM/AUX
NEUTRAL
NOTE: BATTERY PACK AND SWITCH ARE LOCATED IN THE
MANUAL BAG. THE BATTERY PACK IS TO BE USED ONLY IN
THE CASE OF A POWER OUTAGE.
GREEN
BATTERIES
RED
BLACK
ON/OFF ROCKER SWITCH
DETAIL A
DETAIL A
WIRES WITH LABEL “FOR USE WITH
REMOTE OR WALL SWITCH ONLY”
(LOCATED UNDER FIREPLACE)
*
NOTE: APPLIANCE WILL NOT OPERATE UNLESS PROPERLY
GROUNDED. *MUST ORDER PLUG-ADP SEPARATELY IF
USING THE HEAT-ZONE.
NOTE: IGNITION MODULE, VALVE, PILOT
AND WALL SWITCH OPERATE ON 3 VOLTS.