beautypg.com

Top vent - vertical termination - (continued), Three elbows – Heat & Glo Fireplace HEAT & GLO Escape-42DV User Manual

Page 28

background image

Heat & Glo • Escape-42DV • 2052-900 Rev. Y • 11/11

28

Figure 7.8

Top Vent - Vertical Termination - (continued)

INSTALLED

HORIZONTALLY

H

1

H

2

V

1

V

2

Three Elbows

V

1

H

1

H

2

V

2

H

t

Max.

2 ft.

610 mm

*

*

**

7 in

178 mm

3 ft.

914 mm

*

*

**

2 ft.

610 mm

4 ft.

1.2 m

*

*

**

4 ft.

1.2 m

5 ft.

1.5 m

*

*

**

8 ft.

2.4 m

6 ft.

1.8 m

*

*

**

12 ft.

3.7 m

7 ft.

2.1 m

*

*

**

14 ft.

4.3 m

10 ft.

3.0 m

*

*

**

20 ft.

6.1 m

*H

1

and H

2

has no specifi c restrictions EXCEPT,

after V

1

= 6 ft., then H

t

Max = 2 x V

1

**V

T

+ H

T

= 60 ft. Max.

Note: Must have a 24 inches mini-

mum vertical vent before attaching

any elbow to the unit.

Note: A fl ue restrictor can only

be used in vent runs that in-

clude no elbows and exceed

30 ft. total of straight vertical.