Top vent - horizontal termination - (continued) h, Three elbows – Heat & Glo Fireplace HEAT & GLO Escape-42DV User Manual
Page 26
![background image](/manuals/89469/26/background.png)
Heat & Glo • Escape-42DV • 2052-900 Rev. Y • 11/11
26
Figure 7.5
Top Vent - Horizontal Termination - (continued)
H
2
H
1
V
2
V
1
Three Elbows
V
1
H
1
V
2
H
2
2 ft.
610 mm
7 in
178 mm
*
H
2
Max = 2 X V
2
3 ft.
914 mm
2 ft.
610 mm
*
H
2
Max = 2 X V
2
4 ft.
1.2 m
4 ft.
1.2 m
*
H
2
Max = 2 X V
2
5 ft.
1.5 m
9 ft.
2.7 m
*
H
2
Max = 2 X V
2
6 ft.
1.8 m
12 ft.
3.7 m
*
H
2
Max = 2 X V
2
7 ft.
2.1 m
14 ft.
4.3 m
*
H
2
Max = 2 X V
2
10 ft.
3.0 m
20 ft.
6.1 m
*
H
2
Max = 2 X V
2
V
1
+ H
1
must be adhered to.
* V
2
has no specifi c restrictions EXCEPT,
H
t max
= 2 x V
t
and V
total
+ H
total
cannot exceed 60 ft. Maximum
Note: Must have a 24 inches mini-
mum vertical vent before attaching
any elbow to the unit.
Note: A fl ue restrictor can only
be used in vent runs that in-
clude no elbows and exceed
30 ft. total of straight vertical.