Top vent - horizontal termination - (continued) h, Three elbows – Heat & Glo Fireplace HEAT & GLO Escape-42DV User Manual

Page 26

background image

Heat & Glo • Escape-42DV • 2052-900 Rev. Y • 11/11

26

Figure 7.5

Top Vent - Horizontal Termination - (continued)

H

2

H

1

V

2

V

1

Three Elbows

V

1

H

1

V

2

H

2

2 ft.

610 mm

7 in

178 mm

*

H

2

Max = 2 X V

2

3 ft.

914 mm

2 ft.

610 mm

*

H

2

Max = 2 X V

2

4 ft.

1.2 m

4 ft.

1.2 m

*

H

2

Max = 2 X V

2

5 ft.

1.5 m

9 ft.

2.7 m

*

H

2

Max = 2 X V

2

6 ft.

1.8 m

12 ft.

3.7 m

*

H

2

Max = 2 X V

2

7 ft.

2.1 m

14 ft.

4.3 m

*

H

2

Max = 2 X V

2

10 ft.

3.0 m

20 ft.

6.1 m

*

H

2

Max = 2 X V

2

V

1

+ H

1

must be adhered to.

* V

2

has no specifi c restrictions EXCEPT,

H

t max

= 2 x V

t

and V

total

+ H

total

cannot exceed 60 ft. Maximum

Note: Must have a 24 inches mini-

mum vertical vent before attaching

any elbow to the unit.

Note: A fl ue restrictor can only

be used in vent runs that in-

clude no elbows and exceed

30 ft. total of straight vertical.