Uninterruptible Power
Systems – Rack

HP UPS R5500 XR, (5000VA, 4500 Watt), High Voltage (NA/Jpn)

326529-D71

HP UPS R5500 XR, (6000VA, 5400 Watt), High Voltage (Int'l)

326529-B31

HP UPS R1500 XR (100 to 127) (NA)

204404-001

HP UPS R1500 XR (208 to 480) (Int'l)

204404-B31

HP UPS R1500 XR (100 to 127) (Japan)

204404-291

HP UPS R3000 XR (120V) (NA)

192186-001

HP UPS R3000 XR (208V) (NA)

192186-002

HP UPS R3000 XR (100V) (Japan)

192186-291

HP UPS R3000 XR (208V) (Japan) Compaq UPS R3000 XR (200V) (Japan)

192186-292

HP UPS R3000 XR (230V) (Int'l - detachable cord)

192186-B31

HP UPS R3000 XR (230V) (16A IEC309 Plug)

192186-B32

HP UPS R3000 XR (230V) (16A CEE 7/7 SCHUKO Plug)

192186-B33

HP UPS R3000 XR (230V) (16A BS-546 Plug)

192186-AR1

HP Power Distribution
Unit with Power
Monitoring

HP Power Distribution Unit with Power Monitoring Model S2324 - dual input, 3
phase, 24A (NA/JPN)

370959-D71

HP Power Distribution Unit with Power Monitoring Model S1324 - single input, 3
phase, 24A (NA/JPN)

370960-D71

HP Power Distribution Unit with Power Monitoring Model S2140 - dual input, 1
phase, 40A (NA/JPN)

370961-D71

HP Power Distribution Unit with Power Monitoring Model S1140 - single input, 1
phase, 40A (NA/JPN)

370962-D71

HP Power Distribution Unit with Power Monitoring Model S2316 - dual input, 3
phase, 16A (INTL)

370963-B31

HP Power Distribution Unit with Power Monitoring Model S1316 - single input, 3
phase, 16A (INTL)

370964-B31

HP Power Distribution Unit with Power Monitoring Model S2132 - dual input, 1
phase, 32A (INTL)

370965-B31

HP Power Distribution Unit with Power Monitoring Model S1132 - single input, 1
phase, 32A (INTL)

370966-B31

Modular PDUs – 1U/0U
(up to 32 outlets)

NOTE: 1U/0U mounting
brackets shipped with
the unit (optimized for
10000
and 9000 series racks).

HP Modular Power Distribution Units (mPDU), Low Volt Model, 24A (100-127
VAC) (NA, Japan)

NOTE: The above mPDU may also be used to connect to the low volt model of
the UPS R3000 XR.

252663-D71

HP Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240
VAC) (NA, Japan)

NOTE: L6-30 input.

252663-D72

HP Modular Power Distribution Units (mPDU), High Volt Model, 32A (200-240
VAC) (Int'l)

252663-B31

HP Modular Power Distribution Units (mPDU), High Volt Model, 40A (200-240
VAC) (WW)

NOTE: The 40A model has a hardwired input.

252663-B21

HP Modular Power Distribution Units (mPDU), High Volt Model, 16A (200-240
VAC) (WW)

NOTE: This PDU has a detachable input power cord and allows for adaptability
to country specific power requirements. This model may also be used with the
high volt UPSs R3000 XR and R6000.

252663-B24

HP Modular Power Distribution Unit (mPDU), High Volt Model, 40A, Attached
Cord, (NA/JPN)

252663-D73

QuickSpecs

HP ProLiant ML330 Generation 3

Options

DA - 11614 Worldwide QuickSpecs — Version 44 — 6.28.2005