Warning, Type c - 45° elbow in corner installation, F. horizontal termination – Hearth and Home Technologies GARNET-MBK User Manual

Page 12

background image

Page 12

September 1, 2008

Quadra-Fire · Garnet-T · 7016-127F

Female Locking Lugs

Male Locking Lugs

Step 1.
Determine the desired location of the appliance. Check to
ensure that wall studs or roof rafters are not in the way when
the venting system is attached. If this is the case, you may
want to adjust the location of the appliance.

F. Horizontal Termination

Figure 5.4

Figure 5.3

Rear Installations for Use with
Rear Vent Kit

Type B -

Up & Out Installations for Top
Vent Configurations

Type A -

Type C - 45° Elbow in Corner Installation

90º ELBOW

PIPE LENGTH

PIPE LENGTH

WALL THIMBLE

center line

WALL THIMBLE COVER

TERMINATION CAP

CENTER LINE

W AL L THIMBL E

W AL L THIMBLE COVER

17-3/4 in.

(451mm)

TERMINATION CAP

45° Elbow

2 in. (51mm) Clearance from stove
corner to combustible wall.

2 in. (51mm)
Clearance from stove
corner to combustible
wall

Wall Thimble

Step 1.
Determine the desired location of the appliance. Check to
ensure that wall studs or roof rafters are not in the way when
the venting system is attached. If this is the case, you may
want to adjust the location of the appliance.

Step 2.
Direct vent pipe is designed with a locking connection. To
connect the venting system to the appliance flue outlet, a
twist-lock adapter is built into the appliance at the factory.
Wall thickness may vary. Remember to include wall
thickness in minimum clearances when figuring venting
lengths for your installation needs.

Note: Female ends of direct vent pipe/elbows are
designed to slide straight onto the male ends of adjacent
pipes by orienting the pipe indentations so they match and
slide into the entry slots on the male ends, see Figure 5.4.
Push the pipe sections completely together, then twist-lock
one section clockwise approximately one-quarter turn, until
the two sections are fully locked. The female locking lugs
may not be visible from the outside. They may be located by
examining the inside of the female ends.

Fire Hazard.

Exhaust Fume Risk.

Impaired Performance of Appliance.

WARNING

• Ensure vent components are locked together correctly.

• Pipe may separate if not properly joined.