1 setting the mechanical stops of joints #1 and #2 – Epson G10 Series User Manual
Page 72

Setup & Operation 5. Motion Range
62
G10 / G20 Rev.2
5.2.1 Setting the Mechanical Stops of Joints #1 and #2
Both Joints #1 and #2 have threaded holes in the positions corresponding to the angle for
the mechanical stop settings. Install the bolts in the holes corresponding to the angle that
you want to set.
a
b
c
d
e
f
g
h
Joint #1 Mechanical Stops
Joint #1
Mounting Arm
Length
a b c d e f g h
Table Top 65/85/A0
Ceiling
85/A0
+152
°
-152°
Ceiling
65
Wall
65/85/A0
+107
° +60° +15°
-15°
-60°
-107°
a b c d e f g h
Setting Angle
+152
°
+107
° +60° +15°
-15°
-60°
-107°
-152°
Pulse Value +7048761 +5738041 +4369067 +3058347 +2184534
+873814
-495161 -1805881
(°: degree)
This manual is related to the following products: