beautypg.com

3 max. pulse range of joint #3, 4 max. pulse range of joint #4 – Epson G10 Series User Manual

Page 70

background image

Setup & Operation 5. Motion Range

60

G10 / G20 Rev.2

5.1.3 Max. Pulse Range of Joint #3

The 0 (zero) pulse position of Joint #3 is the position where the shaft is at its upper limit.
The pulse value is always negative because Joint #3 always moves lower than the 0 pulse
position.

Upper limit: 0 pulse

Model

Joint #3 Stroke

Minimum Limit Pulse

G10/G20-**1S* 180

mm

-1946420

G10/G20-**4S* 420

mm

-2270823

G10/G20-**1C* 150

mm

-1622016

G10/G20-**4C* 390

mm

-2108621

)

NOTE

For the Cleanroom-model (G10/G20-***C*), the motion range set with the Joint #3
mechanical stop cannot be changed.

5.1.4 Max. Pulse Range of Joint #4

The 0 (zero) pulse position of Joint #4 is the position where the flat near the end of the
shaft faces toward the end of Arm #2. With the 0 pulse as a starting point, the
counterclockwise pulse value is defined as the positive (+) and the clockwise pulse value
is defined as the negative (-).

+Y

+X

Clockwise (-value)

Counterclockwise (+value)

G10

0 pulse

±1951517 pulse

G20

0 pulse

±2752512 pulse

This manual is related to the following products: