beautypg.com

7 user wires and pneumatic tubes, Electrical wires, Pneumatic tubes – Epson G10 Series User Manual

Page 48

background image

Setup & Operation 3. Environments and Installation

38

G10 / G20 Rev.2

3.7 User Wires and Pneumatic Tubes

CAUTION

■ Only authorized or certified personnel should be allowed to perform wiring.

Wiring by unauthorized or uncertified personnel may result in bodily injury and/or
malfunction of the robot system.

User electrical wires and pneumatic tubes are contained in the cable unit.

Electrical Wires

Rated Voltage

Allowable

Current

Wires

Nominal Sectional Area Outer Diameter

Note

AC/DC30 V

1 A

15

0.211 mm

2

ø8.3

±0.3 mm Shielded

Maker

Standard

Suitable Connector

JAE

DA-15PF-N (Solder

type)

15 pin

Clamp Hood

JAE

DA-C8-J10-F2-1R

(Connector setscrew: #4-40 NC)

Suitable Connector

JAE

DE9PF-N (Solder

type)

9 pin

Clamp Hood

JAE

DE-C8-J9-F2-1R

(Connector setscrew: #4-40 NC)

Pins with the same number, indicated on the connectors on both ends of the cables, are

connected.

Pneumatic Tubes

Max. Usable Pneumatic Pressure

Pneumatic Tubes

Outer Diameter × Inner Diameter

2

ø6 mm

Ч ш4 mm

0.59 MPa (6 kgf/cm

2

: 86 psi)

2

ø4 mm

Ч ш2.5 mm

Fittings for ø6 mm and ø4 mm (outer diameter) pneumatic tubes are supplied on both ends

of the pneumatic tubes.

Common Parts

Fitting (white) for

ø6 mm pneumatic tube

Fitting (black) for

ø6 mm pneumatic tube

Brake release

button switch

15-pin D-sub connector

Fitting (black) for

ø4 mm pneumatic tube

Fitting (white) for

ø4 mm pneumatic tube

9-pin D-sub connector

This manual is related to the following products: