/ Speci

fi

cations - Cabinet

Burner

Auxiliary

Semi-rapid

Rapid

Dual burner

Injector

diam.[mm]

0.90
0.54
1.18
0.70
1.55
0.92
0.80+2.10
0.50+1.20

Gas

Type

NG
LP (Propane)
NG
LP (Propane)
NG
LP (Propane)
NG
LP (Propane)

Pressure

[iwc]

4’’
10’’
4’’
10’’
4’’
10’’
4’’
10’’

Max Rate

[Btu/hr]

3,500
3,300
5,900
5,500
10,400
9,500
19,000
19,000

Min Rate

[Btu/hr]

900
900
1,500
1,500
2,500
2,500
1,300
1,300

[W]

1,025
967
1,729
1,611
3,047
2,783
5,567
5,567

[W]

264
264
439
439
732
732
381
381

By-pass

diam.[mm]

Regulated
0.29
Regulated
0.36
Regulated
0.47
Regulated
0.34/0.65

See use and care manual for the layout of the surface burners of your rangetop

Burner

Injector

Gas

Pressure Max Rate

Min Rate

By-pass

Cabinet Preparation

1. To ensure professional results, the cabinet and
countertop openings should be prepared by a
quali

fi

ed cabinet worker.

2. The clearances shown in

fi

gure are required.

3. The gas and electrical supply must be locat-
ed in an area that is accessible without requiring
removal of the cooktop. The appliance electrical
power cord and gas pipe connection are located
on the left rear.

• Prepare

the

fi

nished opening for the rangetop

according to dimensions shown in the
illustration on the follows page.

• The platform must include a cut-out at the right

rear for electrical and gas supply connections.
It must be level to ensure the cooking surface
is level. Refer to the chart below for minimum
base support.

BASE SUPPORT MIN
36” rangetop 250 lb (113 kg)
48” rangetop 300 lb (136 kg)

WARNING

To prevent possible damage to cabinets and ca-
binet

fi

nishes, use only materials and

fi

nishes that

will not discolor or delaminate and will withstand
temperatures up to 230°F (110°C). Heat resistant
adhesive must be used if the product is to be in-
stalled in laminated cabinetry. Check with your
builder or cabinet supplier to make sure that the
materials meet these requirements.