Bertazzoni Master Series 36 Inch Gas Rangetop Installation, Use & Care Manual User Manual
Page 10
10
/ Installation requirements / Electrical connection
ELECTRICAL
A properly-grounded horizontally- mounted electri-
cal receptacle should be installed no higher than
27” (68.6 cm) above the
fl
oor, no less than 2” (5
cm) and no more than 15” (38,1 cm) from the left
side (facing product).
Check all local code requirements.
GAS
An agency-approved, properly-sized manual
shut-o
ff
valve should be installed no higher than
27” (68.6 cm) above the
fl
oor and no less than 2”
(5 cm) and no more than 15” (38.1 cm) from the
right side (facing product).
To connect gas between shut-o
ff
valve and regula-
tor, use agency-approved, properly sized
fl
exible
or rigid pipe. Check all local code requirements.
Warning!
ELECTRICAL SHOCK HAZARD
Disconnect electrical power at the circuit bre-
aker box or fuse box before installing the ap-
pliance.
Provide appropriate ground for the appliance.
Use copper conductors only.
Failure to follow these instructions could re-
sult in serious injury or death.
This unit is manufactured for a polarized, groun-
ded 120 volt/60 Hz, 16 amp system.
Electric power consumption is about 200 W for
36”, 1200W for 48”
The minimum of 102 VAC is required for proper
operation of gas ignition systems.
The circuit must be grounded and properly pola-
rized.
The unit is equipped with a SJT power cord and
a NEMA 5-15P plug. In case of replacement, the
power cord shall be replaced with one of the same
type, size and length.
Warning!
Electrical grounding
This appliance is equipped with a three-prong
plug for your protection against shock hazard and
should be plugged directly into a properly groun-
ded socket. Do not cut or remove the grounding
prong from this plug.
Caution
Label all wires prior to disconnecting when
servicing controls. Wiring errors can cause
improper and dangerous operation.
Verify proper operation after servicing.
INSTALLATION REQUIREMENTS
ELECTRICAL CONNECTION
installation area for the connection
E
G
15''
15''
27''
PLQ
PD[